{"id":13629,"date":"2024-11-07T11:54:40","date_gmt":"2024-11-07T10:54:40","guid":{"rendered":"https:\/\/lga-geo.de\/?post_type=schadstoff&#038;p=13629"},"modified":"2024-11-22T11:57:14","modified_gmt":"2024-11-22T10:57:14","slug":"hbcd","status":"publish","type":"schadstoff","link":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/","title":{"rendered":"HBCD"},"content":{"rendered":"<p class=\"wp-block-paragraph\">HBCD or HBCDD stands for hexabromocyclododecane and is a ring-shaped, brominated hydrocarbon molecule. Due to its technical properties, HBCD was primarily used as a flame retardant for plastics and was therefore mainly used in&nbsp;<strong>Building insulation materials made of polystyrene (EPS \/ XPS)<\/strong>partly also&nbsp;<strong>in packaging plastics (EPS)<\/strong>&nbsp;for use. In May 2013, HBCD was categorised as a persistent pollutant (POP) under the international Stockholm Convention. This resulted in a worldwide ban on trade and use (with transitional periods). Since 22 March 2016, products (substances, mixtures and articles) containing more than 100 mg\/kg HBCD may no longer be manufactured and sold in the EU. A temporary exemption for polystyrene (EPS) ended on 21 February 2018. Insulation materials containing HBCD are not classified as \"hazardous waste\" in Germany, but there is a separate collection requirement, a mixing ban and obligations to provide evidence and keep records.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2.jpg\"><img decoding=\"async\" width=\"1807\" height=\"1358\" data-id=\"13630\" src=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2.jpg\" alt=\"\" class=\"wp-image-13630\" srcset=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2.jpg 1807w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2-960x721.jpg 960w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2-768x577.jpg 768w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2-1536x1154.jpg 1536w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-2-16x12.jpg 16w\" sizes=\"(max-width: 1807px) 100vw, 1807px\" \/><\/a><figcaption class=\"wp-element-caption\">Polystyrene insulation boards under roof cladding<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3.jpg\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"13631\" src=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3.jpg\" alt=\"\" class=\"wp-image-13631\" srcset=\"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3.jpg 1024w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3-960x720.jpg 960w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3-768x576.jpg 768w, https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-3-16x12.jpg 16w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Extruded polystyrene insulation boards (green) in the floor structure<\/figcaption><\/figure>\n<\/figure>","protected":false},"featured_media":13632,"template":"","class_list":["post-13629","schadstoff","type-schadstoff","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HBCD - LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HBCD - LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH\" \/>\n<meta property=\"og:description\" content=\"HBCD bzw. HBCDD steht f\u00fcr Hexabromcyclododecan und ist ein ringf\u00f6rmiges, bromiertes Kohlenwasserstoffmolek\u00fcl. HBCD diente wegen seiner technischen Eigenschaften vorwiegend als Flammschutzmittel f\u00fcr Kunststoffe und kam daher vor allem&nbsp;in&nbsp;Geb\u00e4ude-D\u00e4mmstoffen aus Polystyrol (EPS \/ XPS), teilweise auch&nbsp;in Verpackungskunststoffen (EPS)&nbsp;zum Einsatz. Im Mai 2013 wurde HBCD unter der internationalen Stockholm-Konvention als persistenter Schadstoff (POP) eingestuft. Daraus folgte ein [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/\" \/>\n<meta property=\"og:site_name\" content=\"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-22T10:57:14+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/\",\"url\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/\",\"name\":\"HBCD - LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lga-geo.de\\\/wp-content\\\/uploads\\\/hbcd-1.jpg\",\"datePublished\":\"2024-11-07T10:54:40+00:00\",\"dateModified\":\"2024-11-22T10:57:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lga-geo.de\\\/wp-content\\\/uploads\\\/hbcd-1.jpg\",\"contentUrl\":\"https:\\\/\\\/lga-geo.de\\\/wp-content\\\/uploads\\\/hbcd-1.jpg\",\"width\":1788,\"height\":1349,\"caption\":\"Polystyrolplatten zur W\u00e4rmed\u00e4mmung im Wandbereich\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/schadstoff\\\/hbcd\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"LGA\",\"item\":\"https:\\\/\\\/lga-geo.de\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HBCD\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/\",\"name\":\"LGA geo\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#organization\",\"name\":\"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH\",\"url\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/lga-geo.de\\\/wp-content\\\/uploads\\\/Favicon-IUA-Welle.png\",\"contentUrl\":\"https:\\\/\\\/lga-geo.de\\\/wp-content\\\/uploads\\\/Favicon-IUA-Welle.png\",\"width\":2134,\"height\":2134,\"caption\":\"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/lga-geo.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HBCD - LGA Institute for Environmental Geology and Contaminated Sites GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/","og_locale":"en_GB","og_type":"article","og_title":"HBCD - LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH","og_description":"HBCD bzw. HBCDD steht f\u00fcr Hexabromcyclododecan und ist ein ringf\u00f6rmiges, bromiertes Kohlenwasserstoffmolek\u00fcl. HBCD diente wegen seiner technischen Eigenschaften vorwiegend als Flammschutzmittel f\u00fcr Kunststoffe und kam daher vor allem&nbsp;in&nbsp;Geb\u00e4ude-D\u00e4mmstoffen aus Polystyrol (EPS \/ XPS), teilweise auch&nbsp;in Verpackungskunststoffen (EPS)&nbsp;zum Einsatz. Im Mai 2013 wurde HBCD unter der internationalen Stockholm-Konvention als persistenter Schadstoff (POP) eingestuft. Daraus folgte ein [&hellip;]","og_url":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/","og_site_name":"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH","article_modified_time":"2024-11-22T10:57:14+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/","url":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/","name":"HBCD - LGA Institute for Environmental Geology and Contaminated Sites GmbH","isPartOf":{"@id":"https:\/\/lga-geo.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/#primaryimage"},"image":{"@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/#primaryimage"},"thumbnailUrl":"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-1.jpg","datePublished":"2024-11-07T10:54:40+00:00","dateModified":"2024-11-22T10:57:14+00:00","breadcrumb":{"@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/#primaryimage","url":"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-1.jpg","contentUrl":"https:\/\/lga-geo.de\/wp-content\/uploads\/hbcd-1.jpg","width":1788,"height":1349,"caption":"Polystyrolplatten zur W\u00e4rmed\u00e4mmung im Wandbereich"},{"@type":"BreadcrumbList","@id":"https:\/\/lga-geo.de\/en\/schadstoff\/hbcd\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"LGA","item":"https:\/\/lga-geo.de\/de\/"},{"@type":"ListItem","position":2,"name":"HBCD"}]},{"@type":"WebSite","@id":"https:\/\/lga-geo.de\/en\/#website","url":"https:\/\/lga-geo.de\/en\/","name":"LGA geo","description":"","publisher":{"@id":"https:\/\/lga-geo.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lga-geo.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/lga-geo.de\/en\/#organization","name":"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH","url":"https:\/\/lga-geo.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/lga-geo.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/lga-geo.de\/wp-content\/uploads\/Favicon-IUA-Welle.png","contentUrl":"https:\/\/lga-geo.de\/wp-content\/uploads\/Favicon-IUA-Welle.png","width":2134,"height":2134,"caption":"LGA Institut f\u00fcr Umweltgeologie und Altlasten GmbH"},"image":{"@id":"https:\/\/lga-geo.de\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/lga-geo.de\/en\/wp-json\/wp\/v2\/schadstoff\/13629","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lga-geo.de\/en\/wp-json\/wp\/v2\/schadstoff"}],"about":[{"href":"https:\/\/lga-geo.de\/en\/wp-json\/wp\/v2\/types\/schadstoff"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lga-geo.de\/en\/wp-json\/wp\/v2\/media\/13632"}],"wp:attachment":[{"href":"https:\/\/lga-geo.de\/en\/wp-json\/wp\/v2\/media?parent=13629"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}